Programmable Electronic Battery Discharger with AH Meter Model EBD-151AH / EBD-301AH / EBD-601AH

Programmable Electronic Battery Discharger with AH Meter
Model EBD-151AH / EBD-301AH / EBD-601AH

 
 
 
EBD-151AH / EBD-301AH / EBD-601AH
 
Features
 
  • Discharge Capacity up to 600 Watt in a very compact, light weight and rugged unit.
  • Programmable functions for controlling discharge AH and cut off voltage.
  • Very simple front panel adjustment for precise setting of Discharge rate and display of Battery voltage and current on separate DPMs.
  • Constant Current (CC) and Constant Power (CP) mode of discharge for checking Battery Performance as per international specification.
  • Battery Discharge rate in watt can be viewed by simple sliding of a switch.
  • Convient Handle to carry for field operation of the unit.
  • Small foot print of only 145 mm (W) X 245 mm (D) saving space on test bench.
  • Fully protected against Battery Reverse Connection, Over Power, Over Temperature and Over voltage.
 
Applications:
  • Programmable functions allow the user to measure and compare discharge rates of different batteries. The comparison of AH rating can also be made using voltage cut off function.
  • R&D Dept. of Battery manufacture.
  • To check Battery performance in QC Dept. of Battery manufacturer or bulk user.
  • To compare performance of different types of Batteries for vender approval.
  • For discharge of Batteries in the field before recharging to improve Battery reliability and performance.
  • Solar power system can be checked using constant power function.
  • Suitable for discharging of different types of Batteries such as SMF, Lead Acid, Tabular, GEL, AGM, VRLA, Ni-Cd, NI-MH, Stationery, Traction. Power can be checked using this Battery discharger.
Specifications:
  Model   EBD – 151AH EBD – 301AH EBD – 601AH
1. Input Voltage : 4 – 60 VDC
2. Input Current : 0 – 30 Amp. 0 – 60 Amp. 0 – 120 Amp.
3. Input Power (Max.) : 150 W 300 W 600 W
4. Operational Mode    
  CC / CP Switch : CC: Constant Current Mode.(The change in current is 0.2A or 0.5% of the adjusted value whichever is higher, over entire input voltage range.)
CP: Constant Power Mode.(Change in Power is +/- 6W or 0.5% of the adjusted value whichever is higher, over entire input voltage range.)
5. Load Switch : To Turn ON / Turn OFF Load
6. Load Adjustment : Through 10 Turn multiturn pot with indicating dial
7. Load Adjustment Range    
  HI / LO Switch : HI : 100 % of the range
LO : Approximate 10 % of the range
8. Protection Circuit :  
  Over Power : 170 W +/- 15 W 325 W +/- 20 W 630 W +/- 25 W
  Over Voltage : 65 V +/- 2V
  Over Temperature : Internal Temp. Limited to 90 deg. C +/- 2 deg. C
  Reverse Input : Up to 65V
9. Programming Mode :  
  (i)AH Programming : Setting Discharge in AH: AH meter can be programmed to set for Limiting value of AH. Maximum settable value is 9999 AH.
AH meter is set for UP counting. After discharging AH up to set value, it will switch off discharger. Voltage DPM will indicate Battery voltage at the end of Discharge cycle.
  (ii)Cut-Off voltage
programming
: To Check how much AH is delivered before Battery reaches cut-off voltage, this mode is used. Cut-off voltage can be set between 2V to 60V with resolution of 100mV. AH meter will indicate AH discharged from battery to reach cut-off voltage.
10. Operating Ambient : 0 deg. C - 40 deg. C
11. Meters :  
  Voltage : 3 1/2 Digit DPM Range - 200 VDC Resolution 100mV
  Current/Power : 3 1/2 Digit DPM to indicate either current in Amps or Power in watts by a selector switch.
Current range 200 ADC Resolution : 100mA
Power range 2000 watts Resolution : 1 watt
12. Indicators : (1) Load ON - GREEN LED
(2) Alarm in the event of Over voltage, Over Power, Over Temperature, or Reverse input - RED LED
13. Terminals for DC  
3 pos TB each for +ve and -ve Input M8 (8 mm) Stud with 8 mm Nut, one each for +ve and –ve.
14. Parallel Operation : Possible.
15. Cooling Method : Forced Air by Built in Fan
16. Dimension : 350(H) x 145(W) x 245(D) mm
17. Weight : 6.5 Kg 7.5 Kg 10 Kg.
18. Power : 230V ± 10% AC 50Hz.
      (Optionally 110V +/- 10% AC 50Hz / 60Hz operation can also be supplied )
 
 
 
Home | Products | ELECTRONIC LOAD > SELF ENERGIZED | 100W |  BASIC | 150W  | 300W | 600W | 1200W | 1800W | 2400W | FULL FUNCTION  | 150W | 300W  | 600W | 1200W  | 1800W | 2400W
ELECTRONIC BATTERY DISCHARGER > BASIC | 150W |  300W  | 600W | 1200W  | 1800W | 2400W | PROGRAMMBLE > WITH TIMER  | 150W | 300W  | 600W | WITH AH METER  | 150W  | 300W  | 600W | 
WITH MICRO CONTROLLER  | 150W | 300W | 600W | HIGH CAPACITY BATTERY DISCHARGER > High Capacity Battery Discharge | Contact Us
 
Prime Electronics, Plot No. 39, Opp. Amraiwadi Talavdi, AEC Zonal Office Road, Amraiwadi, Ahmedabad-380026 ,India
Phone: (91) 79 22743671, Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
Copyright © 2011, PRIME Electronics, All Rights Reserved.